The New Carbon Monoxide Detector Law In California- California residents, have you installed a carbon monoxide detector in your home? Per California Senate Bill 183, California residents must have a carbon monoxide detector installed in their home as of July 1, 2011. Although I have been recommending installation of CO alarms in my home inspection reports for some time now, home inspectors will now be required to report on the presence or absence of these detectors. This new law applies to homes having at least one of the following:
- A fossil-fuel burning appliance or heater (wood, gas, oil, coal)
- An attached garage
- A fireplace
Required locations: Carbon monoxide detectors are required to be installed outside of each separate sleeping area in the immediate vicinity of the bedroom(s), and on every level of the home (including basements).
Detectors: Carbon monoxide detectors must be hard-wired with battery backup and must be inter-connected if there is more than one in the home. Solely-battery operated detectors may be used IF alterations done to the home do not result in the removal of wall or ceiling finishes OR there is no access for wiring by means of an attic, basement, or crawlspace.
The carbon monoxide detector must have been tested and certified pursuant to the requirements of the American National Standards Institute (ANSI) and Underwriters Laboratories Inc. (UL) as set forth in ANSI/UL 2034 or ANSI/ UL 2075, and be approved and listed by the Office of the State Fire Marshal. If a combination CO/smoke alarm is used, it must still meet the above standards and the CO detector must sound an alarm that is different than the smoke detector. Carbon monoxide detectors typically can be purchased for $30 and up.
Fines: California law states that anyone who does not comply with the new law may face up to a $200 fine. However, residents will receive a 30-day notice to correct any violations before the fine will be imposed.
The New Carbon Monoxide Detector Law In California- Steve Stenros, owner of First Choice Inspections, is a CREIA MCI home inspector and can be reached for appointment at 888-335-3040. Steve provides professional home inspections in San Diego, Orange and Riverside counties. Clients receive a FREE lifetime appliance RecallChek with every standard home inspection.
Steve Stenros, MCI
Master CREIA Inspector #0115
ICC Residential Combination Inspector #5251439
Certified Infrared Thermographer #7791
FHA/HUD Inspector- #V975
203k Consultant #S0611
888-335-3040
My Recent Home Inspector Blogs:
If You Have These Smoke Alarms, Get Rid Of Them!
The Three Most Common Write-Ups At A Home Inspection
May I Get You Some Carbon Monoxide?
La Jolla Home Inspector Offers Tips On Buying A Foreclosure
Home Inspection Tech Tips: How To Clean Your Rain Gutters
Vacant Homes: Turning Utilities On- San Diego Home Inspector
Sharp-Tipped Screws Are A Hazard To A Home Inspector!
San Diego Home Inspector Goes North
Have You Checked Your Egress Windows?- Encinitas Home Inspector
The New Carbon Monoxide Detector Law In California
"Four Tips For Garage Door Safety"- Encinitas Home Inspector
My Home Inspector Said Aluminum Wiring Will Catch My House On Fire!
Does Your Weep Screed Weep?- Temecula Home Inspector
Hi Steve,
Thanks for the info. I just downloaded a 4-page fine print from the ca.gov site. However after reading through all of it I couldn't find anywhere that it indicated the use of one in the vicinity of each sleeping area.
In your example you have a split plan that shows 2 bedrooms on one side and 1 on the other, needing 2 detectors. If it were a 2-story place without a downstairs bedroom would the two upstairs suffice?
Also, you have that specific code somewhere?
Hi Steve,
Great info as always. My personal preference (contrary to the CBC) is to install at least one CO alarm in a bedroom. http://www.vcstar.com/news/2011/jun/19/carbon-monoxide-poisoning-prevention-act-starts-al/
Interesting. We don't have such a law here in Quebec. It is a good recommendation for any home that has an attached garage, a fireplace or fuel burning appliances. The overhead units are not necessary though as CO gas does not automatically rise like heat and smoke. The units that plug into wall outlets are very practical as there is no concern about batteries getting run down.
Hi Steve, this is an excellent law. Thank you for providing precise information on it's requirements. A great post to pass on to clients.
Steve - I will pay ore attention about carbon monoxide detectors in homes. Thank you for the detailed quality blog on carbon monoxide detector law in California.
Thanks Steve for the needed information, esp. on the correct placement. I have an older manuf. house, and the propane water heater is located on the outside, kinda like a closet (it is well vented at the door and the ceiling of the closet). This is the only gas appliance (no fireplace) for the house. Do I need a detector inside the home?
Lynda: With the scenario you gave, you would need at least one CO detector on each level (one adjacent to each sleeping area, and one on each level). The requirements for new construction must be met by July 1st. CA Residential Code- Section R315 defines where they must be placed. Here it is for your review...
Joe: It's good to see you here on ActiveRain!
Robert: I'm already starting to see a lot of the plug-in units.
Dan: This law will save lives, no doubt. Feel free to pass it on!
John: Your AVI will now include a check box for CO alarms.
Teri: In a manufactured home, the water heater usually sits within the footprint of the home (unless yours is in a storage cabinet completly outside of the exterior wall of the home). I would refer to the local AHJ (Authority Having Jurisdiction) as to whether or not you would need a CO alarm.
Hey Steve, thanks so very much for the detailed info, just had to come back to check it out.
Lynda: Next time you can just check the box at the bottom of the comments section that says "Notify me of new comments" and you'll receive notification!
Hello Steve, when I read the text of the law, I don't see where it says, as you state, "Carbon monoxide detectors must be hard-wired with battery backup and must be inter-connected if there is more than one in the home." Instead, the relevant text of the law says "13262. For purposes of this chapter, the following definitions shall apply: (a) “Carbon monoxide device” means a device that meets all of the following requirements: (1) A device designed to detect carbon monoxide and produce a distinct, audible alarm. (2) A device that is battery powered, a plug-in device with battery backup, or a device installed as recommended by Standard 720 of the National Fire Protection Association that is either wired into the alternating current power line of the dwelling unit with a secondary battery backup or connected to a system via a panel." Section (2) seems to indicate that any one of these devices is acceptable, as opposed to your "must" statement concerning the third option. Do you get your interpretation from another statement elsewhere in this statute, or in another statute entirely? Thanks!
Jeremy, here is section 315 of the CA Residential Code regarding the power supply for carbon monoxide alarms (Note "Exception #2"):
Here is the section regarding interconnection (Note: "Exception #1")...
I realy appreciate your blog and since you are in my area I will definitely keep your information for my clients. Do you happen to have any written information showing that FHA requires the carbon monoxide detectors to be installed? I have an appraiser who has called these out in San Diego, as well as the smoke detectors, and the agent insists the seller does not have to install either of them. Thanks for your help.
Thank you, Roxanna! Since State law mandates their placement, I don't see how this agent can say they are not necessary! If the house is in California, they must be installed. It doesn't matter if it is an FHA loan or not!
It is such an easy fix and there is no reason not to have one( of few if necessary).